Products
Abaqus/Standard
Type
History data
LevelStep
One of the following mutually exclusive parameters is required
-
START
-
Include this parameter to indicate the start of a sequence of steps that will be
cycled.
-
END
-
Include this parameter to indicate the end of a sequence of steps that will be
cycled.
Optional parameters
-
NAME
-
Set this parameter equal to the name of the cycling sequence. This parameter can be
used only in conjunction with the
START parameter.
Step cycling names in the same input file must be unique. Step cycling names from the
original input file cannot be reused in a restart input file.
Data line to define the start of a step cycling sequence
- First line
-
Number of cycles.
Cycle frequency at which to write output. The default is to write output
every cycle.
Cycle frequency at which to create a new output database file . By
default, Abaqus/Standard writes all output to the same output database file.
- Second line (optional)
-
Initial cycle scale factor for use with contact wear.
Maximum cycle scale factor for use with contact wear.
|