LOWER BOUND
-
This parameter is meaningful only in an adjoint design sensitivity analysis.
This parameter is used to specify a lower bound on the design response value below
which adjoint sensitivities are not calculated. That is, if the value of the design
response value is below the specified lower bound, then only the design response value
is written to the output database, but not the corresponding adjoint
sensitivities.
-
NSET
-
Set this parameter equal to the name of the node set for which the nodal design
response value and its sensitivity output are calculated.
-
ORIENTATION
-
This parameter is meaningful only in an adjoint design sensitivity analysis.
Set this parameter equal to the name of an orientation definition to be used to
define a local coordinate system for the node response.
-
OPERATOR
-
This parameter is meaningful only in an adjoint design sensitivity analysis.
Set
OPERATOR=MAX
to indicate that the maximum value of the design response across the node set is
calculated.
Set OPERATOR=
MAXABS to indicate that the maximum absolute value of
the design response across the node set is calculated. This parameter is not available
for design responses in a steady-state dynamic analysis.
Set
OPERATOR=MIN
to indicate that the minimum value of the design response across the node set is
calculated. This value is not supported for direct steady-state dynamic adjoint
sensitivity analysis.
Set
OPERATOR=MINABS
to indicate that the minimum absolute value of the design response across the node set
is calculated. This parameter is not available for design responses in a steady-state
dynamic analysis.
Set
OPERATOR=SUB
to indicate that the difference between the maximum and the minimum values of the
design response across the node set is calculated. This value is not supported for
direct steady-state dynamic adjoint sensitivity analysis.
Set
OPERATOR=AVE
to calculate the average value of the design response over all the nodes in the node
set.
Set
OPERATOR=SUM
(default) to calculate the sum of the design response over all the nodes in the node
set.
-
RANGE OPERATOR
-
This parameter is meaningful only in direct steady-state dynamic adjoint design
sensitivity analysis.
Set
RANGE OPERATOR=AVE
to calculate the average value of the design response over the range of frequencies
specified for the node response.
Set
RANGE OPERATOR=MAX
(default) to calculate the maximum value of the design response over the range of
frequencies specified for the node response.
Set
RANGE OPERATOR=SUM
to calculate the sum of the design response over the range of frequencies specified
for the node response.
-
UPPER BOUND
-
This parameter is meaningful only in an adjoint design sensitivity analysis.
This parameter is used to specify an upper bound on the design response value above
which adjoint sensitivities are not calculated. In other words if the value of the
design response value is above the specified upper bound, then only the design
response value is written to the output database, but not the corresponding adjoint
sensitivities.