*INTERNAL FLUX GENERATION

This option is used to define user-defined internal source terms at the material integration point across multiple physics fields. This option is used in a material data block to define user-defined internal source that can couple multiple physics fields (user subroutine UINTFLUXGEN).

This page discusses:

See Also
In Other Guides
Coupled Thermal-Electrochemical Analysis
UINTFLUXGEN

Products Abaqus/Standard

Type Model data

LevelModel

Required parameters

USER
This parameter is required to activate the usage of user subroutine UINTFLUXGEN.

Optional parameters

PROPERTIES
Set this parameter equal to the number of real (floating point) property values needed as data in user subroutine UINTFLUXGEN. The default is PROPERTIES=0.

Data line to define properties (if the value of PROPERTIES is not set to 0)

First line
  1. Give the properties, eight per line.

Repeat this data line as often as necessary.