ProductsAbaqus/Standard TypeHistory data
LevelStep
Optional parameters
-
LOWER BOUND
-
This parameter is used to specify a lower bound on the design response value below
which adjoint sensitivities are not calculated. That is, if the value of the design
response value is below the specified lower bound, then only the design response value
is written to the output database, but not the corresponding adjoint
sensitivities.
This parameter is not supported in an eigenfrequency sensitivity analysis.
-
UPPER BOUND
-
This parameter is used to specify an upper bound on the design response value above
which adjoint sensitivities are not calculated. That is, if the value of the design
response value is above the specified upper bound, then only the design response value
is written to the output database, but not the corresponding adjoint
sensitivities.
This parameter is not supported in an eigenfrequency sensitivity analysis.
Data
lines - First
line
- Specify an identifying key for the global response whose sensitivities are to be written
to the output database. The valid keys are listed in Adjoint Design Sensitivity Analysis. Only one identifying key can
be specified for each use of this option.
- Second line
-
- Mode number for eigenfrequency
sensitivity.
|