Products
Abaqus/Standard
Abaqus/Explicit
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Step module
Optional parameters
-
ELSET
-
Set this parameter equal to the name of the element set for which this output request
is being made.
-
NSET
-
This parameter applies only to mode-based and direct-solution steady-state dynamic
analyses.
Set this parameter equal to the name of the node set representing the boundary for
energy flow, power flow, radiated acoustic energy, and radiated acoustic power
computations.
The NSET and
SURFACE parameters are mutually
exclusive.
-
SURFACE
-
This parameter applies only to mode-based and direct-solution steady-state dynamic
analyses.
Set this parameter equal to the name of the element-based surface representing the
boundary for energy flow, power flow, radiated acoustic energy, and radiated acoustic
power computations.
The SURFACE and
NSET parameters are mutually
exclusive.
-
PER ELEMENT SET
-
This parameter applies only to Abaqus/Explicit analyses.
Include this parameter to indicate that the requested energy variables are written to
the output database for each user-defined element set (all
internal element sets, including the internal element sets defined in Abaqus/CAE and the internal element sets created during the analysis, are excluded).
-
PER SECTION
-
This parameter applies only to Abaqus/Explicit analyses.
Include this parameter to indicate that the requested energy variables are written to
the output database for every user-defined element set that is associated with a
section definition (all internal element sets, including the
internal element sets defined in Abaqus/CAE and the internal element sets created during the analysis, are excluded).
-
VARIABLE
-
Set
VARIABLE=ALL
to indicate that all energy variables applicable to this procedure and material type
should be written to the output database.
Set
VARIABLE=PRESELECT
to indicate that the default energy output variables for the current procedure type
should be written to the output database. Additional output variables can be requested
on the data lines.
If this parameter is omitted and no energy variables are specified on the data lines,
all energy variables will be written to the output database.
Data lines to request energy output
- First line
-
Specify the identifying keys for the variables to be written to the
output database. The keys are defined in Output Variables.
Repeat this data line as often as necessary to define the energy
variables to be written to the output database.