Products
Abaqus/Standard
Type
Model data
LevelModel
Required parameters
-
DEFINITION
-
Set
DEFINITION=GRINDLING
to define the degree of cure rate using the Grindling equation.
Set
DEFINITION=KAMAL
to define the degree of cure rate using the Kamal equation.
Set
DEFINITION=TABULAR
to define the degree of cure rate in tabular form.
Set
DEFINITION=USER
to define the degree of cure rate using user subroutine UCURE.
Optional parameters
-
DEPENDENCIES
This parameter is relevant only for
DEFINITION=TABULAR
and for
DEFINITION=KAMAL
used in combination with the parameter
NUMBER TERMS.
Set
this parameter equal to the number of field variable dependencies included
in the definition of the degree of cure rate, in addition to temperature. If
this parameter is omitted, the degree of cure rate does not depend on field
variables.
-
NUMBER TERMS
This parameter is relevant only for
DEFINITION=KAMAL.
Set
this parameter equal to the number of terms in the Kamal
model.
-
PROPERTIES
-
This parameter is relevant only for
DEFINITION=USER.
Set this parameter equal to the number of property values needed as data
in user subroutine UCURE. The
default is
PROPERTIES=0.
Data lines to define the Grindling model coefficients
- First line
-
- Grindling equation coefficient,
. (Units of
T-1.)
- Ratio of the activation energy to the universal gas constant,
. (Units of
.)
- Grindling equation exponent,
.
- Grindling equation coefficient,
. (Units of
T-1.)
- Ratio of the activation energy to the universal gas constant,
. (Units of
.)
- Grindling equation exponent,
.
- Grindling equation exponent,
.
- Grindling equation parameter,
.
- Second line
-
- Grindling equation parameter,
. (Units of
.)
- Diffusion-controlled reaction rate at the glass transition
temperature,
. (Units of
T-1.)
- Grindling equation parameter,
. (Units of
.)
In addition, you must specify the value of absolute zero using the PHYSICAL CONSTANTS option
and the glass transition temperature using the CURE GLASS TRANSITION TEMPERATURE
option.
Data lines to define the Kamal model coefficients using
DEFINITION=KAMAL
without the NUMBER TERMS
parameter
- First line
-
Kamal equation coefficient,
. (Units of T-1.)
Ratio of the activation energy to the universal gas
constant,
. (Units of
.)
- Kamal equation exponent,
.
- Kamal equation exponent,
.
- Kamal equation parameter,
.
In addition, you must specify the value of absolute zero using the PHYSICAL CONSTANTS
option.
Repeat this data line as often as necessary to define the second,
third, etc., terms in the Kamal equation. There is no restriction on the number of
terms in the model.
Data lines to define Kamal model coefficients using
DEFINITION=KAMAL
with the NUMBER TERMS
parameter
- First line
-
Kamal equation coefficient,
. (Units of T-1.)
Ratio of the activation energy to the universal gas
constant,
. (Units of
.)
- Kamal equation exponent,
.
- Kamal equation exponent,
.
- Kamal equation parameter,
.
- Etc., specify Kamal model parameters
,
,
,
,
for each term
. (Only needed if the
NUMBER TERMS
parameter has a value greater than 1.)
- Temperature.
- First field variable.
- Subsequent lines (only needed if the number of entries is greater
than eight)
-
- Second field variable.
- Etc., up to eight field variables per line.
In addition, you must specify the value of absolute zero using the PHYSICAL CONSTANTS
option.
Repeat this set of data lines as often as necessary to define the
dependence of Kamal model coefficients on temperature and other predefined field
variables.
Data lines to define the degree of cure rate in tabular
form
- First line
-
- Degree of cure rate,
. (Units of
T-1.)
- Degree of cure,
.
- Temperature.
- First field variable.
- Second field variable.
- Etc., up to five field variables.
- Subsequent lines (only needed if the
DEPENDENCIES parameter has
a value greater than five)
-
- Sixth field variable.
- Etc., up to eight field variables per line.
Repeat this data line as often as necessary to define the
degree of cure rate as a function of the degree of cure, temperature,
and user-defined field variables.
Data lines to define the degree of cure rate in user subroutine
UCURE
- No data lines are needed if the
PROPERTIES parameter is
omitted or set to 0. Otherwise, first line
-
- Enter the values of the cure kinetics properties, eight per
line.
Repeat this data line as often as necessary to define the