Set this parameter equal to the name of the amplitude curve that defines a
time-dependent scale factor for contact stabilization over the step. If this parameter
is omitted, the scale factor ramps linearly from unity to zero over the step.
RANGE
Set this parameter equal to the clearance at which the stabilization becomes zero; no
contact stabilization is applied where the separation between surfaces exceeds this
value. By default, this clearance is calculated by Abaqus/Standard based on the facet sizes on contact surfaces.
REDUCTION PER INCREMENT
Set this parameter equal to a fraction by which contact stabilization is successively
scaled each increment after the first increment. The default value is 0.1 for
interactions specified on the data lines of this option, which leads to scaling of
contact stabilization by 0.1 in the second increment, scaling of contact stabilization
by 0.01 in the third increment, and so forth. This scaling of contact stabilization
acts in combination with other scale factors.
RESET
Include this parameter to cancel carryover effects from contact stabilization
specifications involving nondefault amplitudes that appeared in previous steps. This
parameter cannot be used in conjunction with any other parameters. There are no data
lines if this parameter is included.
SCALE FACTOR
Set this parameter equal to a factor by which Abaqus/Standard will scale the contact stabilization coefficient. The default value is unity for
the interactions specified on the data lines of this option.
Set
SCALE FACTOR=USER ADAPTIVE
to scale the contact stabilization coefficient by a factor that decreases over
iterations within each increment, according to the pattern specified on the data line.
TANGENT FRACTION
Set this parameter equal to a factor that scales the contact stabilization
coefficient in the tangential direction only. The default value is zero, such that no
contact stabilization is applied in the tangential direction.
Data lines if both the RESET
parameter and
SCALE FACTOR=USER ADAPTIVE
are omitted
First line
The name of the first surface. If the first surface name is omitted, a
default surface that encompasses the entire general contact domain (including all
nodes and facets) is assumed.
The name of the second surface. If the second surface name is omitted or
is the same as the first surface name, the specified stabilization settings are
assigned to contact interactions between the first surface and itself.
Repeat this data line as often as necessary. Specifying named
XFEM-based crack surfaces on the data lines is not