ELSET
-
Set this parameter equal to the name of the element set containing the connector
elements for which the connection attributes are being defined.
Optional parameters
-
BEHAVIOR
-
Set this parameter equal to the name of the connector behavior that defines these
connector elements. If this parameter is omitted, the connector element's behavior is
determined by kinematic constraints only.
-
CONTROLS
-
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the name of a section controls definition (see Section Controls) to be used
for the connector elements.
Section controls can be used to specify whether the connector elements should be
deleted once they fail completely. If this parameter is omitted, the failed elements
will not be deleted. Section controls can also be used to specify a maximum value of
the scalar degradation (damage) parameter,
, and to specify the viscosity coefficient,
, for viscous damping or regularization.
-
ELIMINATION
-
This parameter applies only to Abaqus/Explicit analyses.
Set
ELIMINATION=NO
(default) if the constraint or kinetic forces/moments of the associated connector
elements are to be solved for directly in the implicit constraint solver in Abaqus/Explicit.
Set
ELIMINATION=YES
if the constraint or kinetic forces/moments of the associated connector elements are
to be solved for using a condensation technique.
Data lines to define the connection attributes
- First line
-
Basic translational connection type, basic rotational connection type,
assembled connection type, or complex connection type from Connection Types. If an assembled or a complex connection is
selected, no additional data can be entered on this data line.
Basic rotational or basic translational connection component. If the
first entry of this data line is a basic translational connection component, the
second entry (if provided) must be a basic rotational connection component.
Similarly, if the first entry of this data line is a basic rotational connection
component, the second entry (if provided) must be a basic translational connection
component.
- Second line (optional)
-
Orientation name specifying the local directions at the first node (or
ground node) of the connector element.
Orientation name specifying the local directions at the second node (or
ground node) of the connector element. If an orientation name is not specified, the
local directions at the first node are used.
Omit the second line if neither of the two orientations is specified and the third
line is omitted. Leave blank if neither of the two orientations is specified and the
third line is included.
- Third line (optional) for
SLIPRING connection
type
-
Mass per unit reference length of belt material.
Contact angle (in radians) made by belt wrapping around node b
(optional). The value must be zero or positive.
In Abaqus/Standard the default value is 0.0. However, you can leave this data item blank and set the
5th data item to UPDATED ANGLE to have Abaqus/Standard update the contact angle automatically during the analysis. In Abaqus/Explicit if you do not specify the contact angle, Abaqus/Explicit computes it automatically.
Leave this data item blank only if you request the contact angle to be
computed automatically in Abaqus/Standard. Omit it otherwise.
Leave this data item blank only if you request the contact angle to be
computed automatically in Abaqus/Standard. Omit it otherwise.
Optionally, specify UPDATED ANGLE to
request that Abaqus/Standard computes the contact angle automatically during the analysis. If you specify the
contact angle directly as the 2nd data item on this line, Abaqus/Standard ignores the UPDATED ANGLE
setting.
Omit the third line if no data are specified.
- Third line (optional) for
RETRACTOR or
FLOW-CONVERTER connection
types
-
Scaling factor for material flow at node b,
(default value is 1.0).