Products
Abaqus/Standard
Abaqus/CAE
Type
History data
LevelStep
Abaqus/CAE
Step module
Optional parameters
-
EIGENSOLVER
-
Use this parameter to choose the eigensolver.
Set
EIGENSOLVER=SUBSPACE
(default) to invoke the subspace iteration eigensolver.
Set
EIGENSOLVER=LANCZOS
to invoke the Lanczos eigensolver.
Data line for an eigenvalue buckling analysis when
EIGENSOLVER=SUBSPACE
- First (and only) line
-
Number of eigenvalues to be estimated.
Maximum eigenvalue of interest. If this field is left
blank, no maximum is set.
Number of vectors used in the iteration. Abaqus/Standard usually determines this number, but you can change the number
using this entry. In general, the convergence in solving the
eigenproblem is more rapid if more vectors are carried in the
iteration; therefore, use this data field if past experience
suggests that the convergence is slow for a particular type of
buckling problem. If the number of eigenvalues requested is
n, the default number of vectors
used is the minimum of (2n,
n+8).
Maximum number of iterations. The default is
30.
Data line for an eigenvalue buckling analysis when
EIGENSOLVER=LANCZOS
- First (and only) line
-
Number of eigenvalues to be estimated. If the evaluation of
all the eigenvalues in the given range is desired, enter the
maximum number of expected eigenmodes.
Minimum eigenvalue of interest. Providing this value
directs the Lanczos solution procedure to find eigenvalues near
this value with minimal computational effort. Lower eigenvalues
might also be found with no additional computational cost. If
this field is left blank, no minimum is set.
Maximum eigenvalue of interest. Providing this value
directs the Lanczos solution procedure to find eigenvalues near
this value with minimal computational effort. Higher eigenvalues
might also be found with no additional computational cost. If
this field is left blank, no maximum is set.
Block size. If this entry is omitted, a default value,
which is usually appropriate, is created.
Maximum number of block Lanczos steps within each Lanczos
run. If this entry is omitted, a default value, which is usually
appropriate, is created.