The inflator capability in Abaqus/Explicit is suited for modeling the flow characteristics of inflators used for airbag systems. You
must associate the inflator definition with a name. You specify the reference node of the
fluid cavity that the inflator will fill with gas. A single fluid cavity can have any number
of inflators.
The inflator property defines the mass flow rate and temperature as a function of inflation
time either directly or by entering tank test data. It also defines the mixture of gases
entering the fluid cavity. You must associate the inflator property with a name. This name
can then be used to associate a certain property with an inflator definition.
Specifying the Gas Temperature and Mass Flow Rate Directly
The temperature and the mass flow rate of the gas entering the fluid cavity can be given
directly as functions of inflation time. Enter a table of mass flow rate and temperature
versus inflation time.
Input File Usage
FLUID INFLATOR PROPERTY, TYPE=TEMPERATURE AND MASSinflation time, inflator gas temperature, inflator mass flow rate
...
Abaqus/CAE Usage
Interaction module: Create Interaction Property: Fluid inflator, Definition: Temperature and mass: Inflation Time, Inflator Gas Temperature, Inflator Mass Flow Rate
Using Tank Test Data
The mass flow rate and the temperature of the gas entering the fluid cavity can be
determined by the results of a tank test. In the test the inflator is discharged into a
closed, fixed volume tank, and the time history of pressure in the tank is measured. The
inflator mass flow rate can then be calculated from the pressure history using the
equations of gas dynamics. For an ideal gas, conservation of energy for an adiabatic
process is given by
where is the temperature, is the absolute zero on the temperature scale being used, and the
subscripts and refer to quantities in the inflator and the rigid tank, respectively.
Using mass balance
and the equation of state for an ideal gas with constant volume gives
The mass flow rate can be found by combining the above equations
where is the ratio of the constant pressure heat capacity, , and the constant volume heat capacity, :
To calculate the mass flow rate using the results of a tank test, enter a table of tank
pressure and inflator temperature versus inflation time, and specify the volume of the
tank.
Input File Usage
FLUID INFLATOR PROPERTY, TYPE=TANK TEST, TANK VOLUME=
inflation time, inflator gas temperature, tank pressure
...
Abaqus/CAE Usage
Interaction module: Create Interaction Property: Fluid inflator, Definition: Tank test: Tank volume: , Inflation Time, Inflator Gas Temperature, Tank Pressure
Using the Dual Pressure Method
If both the inflator pressure, , and tank pressure, , time history curves can be measured during a tank test, the inflator
mass flow rate and temperature can then be calculated using the assumption of isentropic
flow (Wang and Nefske, 1988). The mass flow rate through the inflator orifice can be
described by
where C is the discharge coefficient, A is the
effective area, and the coefficient is determined by assuming choked or sonic flow as
Comparing the expression for inflator mass flow rate obtained in a rigid tank with that
given above, the inflator temperature is given by
and the inflator mass flow rate is
To calculate the inflator mass flow rate and temperature using the dual pressure method,
enter a table of tank pressure and inflator pressure versus inflation time; and specify
the volume of the tank, the effective area, and the discharge coefficient. The tank volume
and effective area must be specified. The discharge coefficient has a default value of
0.4.
Input File Usage
FLUID INFLATOR PROPERTY, TYPE=DUAL PRESSURE,
TANK VOLUME=, EFFECTIVE AREA=A,
DISCHARGE COEFFICIENT=Cinflation time, inflator pressure, tank pressure
...
Abaqus/CAE Usage
Interaction module: Create Interaction Property: Fluid inflator, Definition: Dual pressure: Effective area: A, Tank volume: , Discharge coefficient: C, Inflation Time, Inflator Pressure, Tank Pressure
Specifying the Inflator Pressure and Mass Flow Rate Directly
You can enter a table of the mass flow rate and inflator pressure versus inflation time
and specify the effective area and discharge coefficient. The gas temperature in the
inflator will be calculated by using the assumption of isentropic flow. The effective area
must be specified. The discharge coefficient has a default value of 0.4.
Input File Usage
FLUID INFLATOR PROPERTY, TYPE=PRESSURE AND MASS, EFFECTIVE AREA=A, DISCHARGE COEFFICIENT=Cinflation time, inflator pressure, inflator mass flow rate
...
Abaqus/CAE Usage
Interaction module: Create Interaction Property: Fluid inflator, Definition: Inflator pressure and mass flow rate: Effective area: A, Discharge coefficient: C, Inflation Time, Inflator Pressure, Inflator Mass Flow Rate
Specifying the Gas Mixture
To define the inflator gas mixture, specify the number of gas species used for the
inflator, and enter a list of names of fluid behaviors and a table of the mass fraction or
molar fraction of the species. The mass fraction or molar fraction of the species might be
a function of inflation time. The sum of the mass fractions or molar fractions for the
species should be equal to one at any given time.
Input File Usage
Use the following options to specify the gas mixture in terms of the mass
fractions:
FLUID INFLATOR PROPERTYFLUID INFLATOR MIXTURE, NUMBER SPECIES=k,
TYPE=MASS FRACTIONfluid_behavior_name_1, fluid_behavior_name_2, etc.inflation time, mass fraction 1, mass fraction 2, etc.
...
Use the following options to specify the gas mixture in terms of the molar
fractions:
FLUID INFLATOR PROPERTYFLUID INFLATOR MIXTURE, NUMBER SPECIES=k,
TYPE=MOLAR FRACTIONfluid_behavior_name_1, fluid_behavior_name_2, etc.inflation time, molar fraction 1, molar fraction 2, etc.
...
Abaqus/CAE Usage
Use the following options to specify the gas mixture in terms of the mass
fractions:
Inflator property definition consists of specifying tables of gas variables versus
inflation time. In Abaqus/Explicit the inflation time, , is related to the value of an amplitude curve by
Typically the amplitude variation is a step function stepping from zero to one at the
time the airbag should be deployed. This amplitude variation has the effect of offsetting
the inflation time from the analysis time.
If the mass flow rate is prescribed directly in the inflator property definition, you can
modify it by specifying an amplitude definition during a step. However, if the mass flow
rate is calculated using tank test data or the dual pressure method, the amplitude
definition will be ignored.
By default, when you modify the activation of a fluid inflator definition or activate a
new fluid inflator definition, all existing fluid inflator activations in the step remain.
When modifying an existing activation, all applicable parameters must be respecified.
Activated inflator definitions remain active in subsequent steps unless deactivated. You
can choose to deactivate all fluid inflator definitions in the model and optionally
reactivate new ones. If you deactivate any fluid inflator definition in a step, all fluid
inflator definitions must be respecified.
Input File Usage
Use the following option to modify an existing fluid inflator activation or to
specify an additional fluid inflator activation (default):