Parameter Name |
Formula |
WEIGHT |
|
where is the element weight.
For topology optimization, design elements are scaled with the current
relative density.
Analysis-Independent Design Response
For the weight, the following table shows the allowed combinations
between the strategy and the items OBJ_FUNC
and CONSTRAINT
with C for controller and S for sensitivity-based optimization.
|
TOPO |
SHAPE |
BEAD |
SIZING |
OBJ_FUNC |
S |
C, S |
|
S |
CONSTRAINT |
S |
C, S |
|
S |
The weight term is the same as the volume term except you have the
possibility of constraining your optimization result to have a certain
physical weight. SIMULIA Tosca Structure
requires that the density of all elements is defined in the input file.
In addition, only supported element types are used in the weight calculation.