*HEADING Concrete Slump Test Mohr-Coulomb, Axisymmetric element Friction angle=20, dilation angle=20 *NODE 1, 0.00, 0. 6, 0.10, 0. 101, 0.00, 0.3 106, 0.05, 0.3 *NGEN,NSET=BOT 1,6,1 *NGEN,NSET=TOP 101,106,1 *NFILL,NSET=ALLN BOT,TOP,10,10 *NSET,NSET=CENT,GENERATE 1,101,10 *ELEMENT,TYPE=CAX4R 1,1,2,12,11 *ELGEN,ELSET=ALLE 1,5,1,1,10,10,10 *ELSET,ELSET=OUTE,GENERATE 1,5,1 *SOLID SECTION,ELSET=ALLE,MATERIAL=CONC *MATERIAL,NAME=CONC *ELASTIC 2.25,.125 *MOHR COULOMB ** 20.,20. 50.,50. *MOHR COULOMB HARDENING 1.1547E-3, *DENSITY 0.1, *BOUNDARY CENT,1 BOT,2 *AMPLITUDE, NAME=AMP, DEFINITION=SMOOTH STEP 0.0, 0.0, 30.0, 1.0 *elset, elset=eout 1, 2 *elset, elset=qa_test_elset eout,11,12 *nset,nset=qa_test_nset alln *STEP, NLGEOM=YES Dimensionless Slump Test under Gravity Load *DYNAMIC, EXPLICIT ,30.0 *DLOAD, amplitude=amp ALLE,GRAV,0.6666,0,-1.,0. *OUTPUT,FIELD *NODE OUTPUT,NSET=ALLN U, *NODE OUTPUT,NSET=BOT RF, *ELEMENT OUTPUT S,LE,PE,PEEQ *OUTPUT,HISTORY,VARIABLE=PRESELECT *NODE OUTPUT,NSET=ALLN U, *NODE OUTPUT,NSET=BOT RF, *ELEMENT OUTPUT, elset=eout S, PEEQ, MISES, PRESS ***QA*** *OUTPUT,FIELD,NUM=4 *NODE OUTPUT,NSET=QA_TEST_NSET U, *ELEMENT OUTPUT,ELSET=QA_TEST_ELSET PEEQ *END STEP