*HEADING Concrete Slump Test Cast Iron Plasticity, Axisymmetric element *NODE 1, 0.00, 0. 6, 0.10, 0. 101, 0.00, 0.3 106, 0.05, 0.3 *NGEN,NSET=BOT 1,6,1 *NGEN,NSET=TOP 101,106,1 *NFILL,NSET=ALLN BOT,TOP,10,10 *NSET,NSET=CENT,GENERATE 1,101,10 *ELEMENT,TYPE=CAX4R 1,1,2,12,11 *ELGEN,ELSET=ALLE 1,5,1,1,10,10,10 *ELSET,ELSET=OUTE,GENERATE 1,5,1 *SOLID SECTION,ELSET=ALLE,MATERIAL=CONC,CONTROLS=SC-1 *SECTION CONTROLS,NAME=SC-1,DISTORTION CONTROL=YES *MATERIAL,NAME=CONC *ELASTIC 2.25,.125 *CAST IRON PLASTICITY 0.2565, *CAST IRON TENSION HARDENING 3.173E-03,0.0 *CAST IRON COMPRESSION HARDENING 5.0E-03,0.0 *DENSITY .1, *BOUNDARY CENT,1 BOT,2 *AMPLITUDE, NAME=AMP, DEFINITION=SMOOTH STEP 0.0, 0.0, 30.0, 1.0 *NSET, NSET=QA_TEST_TOP TOP *ELSET, ELSET=QA_TEST_OUTE OUTE *STEP, NLGEOM=YES Dimensionless Slump Test under Gravity Load *DYNAMIC, EXPLICIT ,30.0 *DLOAD, amplitude=amp ALLE,GRAV,0.6666,0,-1.,0. *OUTPUT,FIELD, NUMBER INTERVAL=4, TIMEMARKS=NO *NODE OUTPUT,NSET=QA_TEST_TOP U, *ELEMENT OUTPUT, ELSET=QA_TEST_OUTE LE,PE *OUTPUT,FIELD *NODE OUTPUT,NSET=ALLN U, *NODE OUTPUT,NSET=BOT RF, *ELEMENT OUTPUT S,LE,PE *OUTPUT,HISTORY,VARIABLE=PRESELECT *NODE OUTPUT,NSET=ALLN U, *NODE OUTPUT,NSET=BOT RF, *END STEP