*RADIATION PRINT

Define print requests for cavity radiation heat transfer.

This option is used to print tabular output of cavity radiation variables (radiation fluxes, view factor totals, and facet temperatures).

This page discusses:

See Also
In Other Guides
Cavity Radiation in Abaqus/Standard
About Output

ProductsAbaqus/Standard

TypeHistory data

LevelStep

Optional, mutually exclusive parameters (if not specified, output will be provided for all cavities in the model)

CAVITY

Set this parameter equal to the name of the cavity for which this output request is being made.

ELSET

Set this parameter equal to the name of the element set for which this output request is being made.

SURFACE

Set this parameter equal to the name of the surface for which this output request is being made.

Optional parameters

FREQUENCY

Set this parameter equal to the output frequency, in increments. The output will always be printed at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set FREQUENCY=0 to suppress the output.

SUMMARY

Set SUMMARY=YES (default) to obtain a summary of the maximum and minimum values in each column of the table and their locations.

Set SUMMARY=NO to suppress this summary.

TOTALS

Set TOTALS=YES to print the total of each column in the table. This is useful, for example, to sum radiation fluxes over all facets composing a radiation surface. The default is TOTALS=NO.

Data lines to request printed output

First line
  1. Give the identifying keys for the variables to be printed in a table for this request. The keys are defined in the “Surface variables” section of Abaqus/Standard Output Variable Identifiers.

Repeat this data line as often as necessary: each line defines a table (or more than one table if the request is for a cavity made up of more than one surface). If this line is omitted, the default variables will be used.