*PSD-DEFINITION

Define a cross-spectral density frequency function for random response loading.

This option is used to define a frequency function for reference in the CORRELATION option to define the frequency dependence of the random loading in the RANDOM RESPONSE analysis procedure.

This page discusses:

See Also
*CORRELATION
*RANDOM RESPONSE
In Other Guides
Random Response Analysis
UPSD

ProductsAbaqus/Standard

TypeModel data

LevelModel

Required parameters

NAME

Set this parameter equal to a label that will be used to refer to this frequency function.

Optional parameters

DB REFERENCE

Set this parameter equal to the reference power value, in (load units)2. This parameter is required when the frequency function is given in decibel units (TYPE=DB).

G

Set this parameter equal to the reference gravity acceleration; for example, 9.81 m/s2. The default is G=1.0. This parameter can be used only with TYPE=BASE.

INPUT

Set this parameter equal to the name of the alternate input file containing the data lines for this option. See Input Syntax Rules for the syntax of such file names. If this parameter is omitted, it is assumed that the data follow the keyword line.

TYPE

Set TYPE=BASE if this frequency function will be used to define a base motion.

Set TYPE=FORCE (default) if this frequency function is given directly in power units.

Set TYPE=DB if this frequency function is defined in decibel units (see below). This option cannot be used with the USER parameter.

USER

Include this parameter if the frequency function is defined in user subroutine UPSD. If this parameter is included, no data lines are needed.

Data lines for TYPE=BASE or TYPE=FORCE

First line
  1. Real part of the frequency function, in units2 per frequency.

  2. Imaginary part of the frequency function, in units2 per frequency.

  3. Frequency, in cycles/time.

Repeat this data line as often as necessary to define the frequency function.

Data lines for TYPE=DB

First line
  1. Real part of the frequency function, in decibels.

  2. Imaginary part of the frequency function, in decibels.

  3. Frequency band number (1–15). Up to 15 standard frequency bands can be used.

Repeat this data line as often as necessary to define the frequency function in decibels.

To define the frequency function by a user subroutine (USER parameter included)

No data lines are used with this option if the USER parameter is specified. Instead, user subroutine UPSD must be used to define the frequency function.