Keep rebar prestress constant during initial equilibrium solution.
This option is used within a STATIC step (Static Stress Analysis) to keep the stress in some or all of the rebar constant during the initial equilibrium solution.
This page discusses:
ProductsAbaqus/Standard
TypeHistory data
LevelStep
Element set name.
Rebar name. The stress in all rebar included in the above element set will be held fixed throughout the step.
Etc.
Repeat this data line as often as necessary. Give four pairs of data per line.