ProductsAbaqus/StandardAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEInteraction module
Required parameters
- NAME
-
Set this parameter equal to a label that will be used to refer to the fluid exchange definition.
- PROPERTY
-
Set this parameter equal to the name of the FLUID EXCHANGE PROPERTY option defining the fluid exchange property.
Optional parameters
- CAVITY PRESSURE
-
This parameter applies only to Abaqus/Explicit analyses.
Set CAVITY PRESSURE=SURFACE (default) to indicate that the fluid pressure from the fluid cavity should be applied on the surface used for fluid exchange.
Set CAVITY PRESSURE=PERIMETER to identify the fluid exchange surface as an open vent and to apply the fluid pressure as an equivalent load on the perimeter of the surface.
- CONSTANTS
-
This parameter applies only to Abaqus/Explicit analyses.
Set this parameter equal to the number of fluid exchange constants needed as data to define the effective area for fluid exchange in user subroutine VUFLUIDEXCHEFFAREA. The default is CONSTANTS=0.
- EFFECTIVE AREA
-
This parameter applies only to Abaqus/Explicit analyses.
Set EFFECTIVE AREA equal to the total area for the exchange. The default value is 1.0 if the SURFACE parameter is omitted. Otherwise, the default value is equal to the area of the surface. If both the EFFECTIVE AREA and SURFACE parameters are specified, the area of the surface is used only to determine blockage and the effective area is reduced to the extent that the surface is blocked.
Set EFFECTIVE AREA=USER to indicate that user subroutine VUFLUIDEXCHEFFAREA in Abaqus/Explicit will be used to define the effective area of the surface taking the local material state into account. The SURFACE parameter is required if user subroutine VUFLUIDEXCHEFFAREA is used.
-
MAX RUPTURE AREA RATIO
-
This parameter applies only to Abaqus/Explicit analyses.
Set this parameter equal to a threshold ratio above which the fluid
cavity is deactivated. The ratio is defined as the surface area from
failed elements over the total surface area associated with this fluid
exchange. This parameter is valid only if
RUPTURE=ON.
-
RUPTURE
-
This parameter applies only to Abaqus/Explicit analyses.
Set
RUPTURE=ON
to allow fluid and/or heat energy to be exchanged over surfaces from
failed elements enclosing a fluid cavity.
Set
RUPTURE=OFF
(default) to indicate that exchanging fluid and/or heat energy over
surfaces from failed elements enclosing the fluid cavity is not
allowed.
- SURFACE
-
This parameter applies only to Abaqus/Explicit analyses.
Set this parameter equal to the name of the surface on the fluid cavity over which fluid and/or
heat energy may be exchanged. If this parameter is omitted, the value
specified with the
EFFECTIVE AREA
parameter is used for the exchange. This parameter is required if
EFFECTIVE AREA=USER
or
RUPTURE=ON.
Data lines to define the fluid exchange
- First line
First reference node number of fluid cavity.
Second reference node number of fluid cavity (required in Abaqus/Standard; optional in Abaqus/Explicit). If you specify only one node in an Abaqus/Explicit analysis, fluid exchange occurs between the fluid cavity and its environment.
- Second line (needed only if the CONSTANTS parameter is used)
Enter the values of the fluid exchange constants to define the effective area for fluid exchange, eight per line.
Repeat this data line as often as necessary to define all properties.