ASSEMBLED
-
Include this parameter to write assembled matrices. By default, element
matrices are written.
-
DAMPING
-
Include this parameter to output the heat capacity matrix.
-
ELSET
-
Use this parameter to write matrices for a part of the model. Set this
parameter equal to the name of an element set that contains all the
elements in the selected part of the model. By default, matrices are
generated for all supported elements in the whole model, including
internal elements.
-
FREQUENCY
-
Set this parameter equal to the output frequency, in increments. The
output will always be written at the last increment of each step unless
FREQUENCY=0. The
default is
FREQUENCY=1. Set
FREQUENCY=0 to
suppress the output.
-
LOAD
-
Include this parameter to output the flux selected by the
LOADTYPE
parameter.
-
LOADTYPE
-
Use this parameter to select the type of load for output.
Set
LOADTYPE=EXTERNAL
(default) to output external heat flux.
Set
LOADTYPE=NET
to output net heat flux.
-
STIFFNESS
-
Include this parameter to output the thermal conductivity matrix.