*ADAPTIVE MESH REFINEMENT

Activate adaptive mesh refinement in an Eulerian domain.

This option is used to activate adaptive mesh refinement in an Eulerian domain and to specify the refinement criteria in that domain.

This page discusses:

See Also
*EULERIAN SECTION
In Other Guides
Eulerian Analysis
Defining Adaptive Mesh Refinement in the Eulerian Domain

ProductsAbaqus/Explicit

TypeModel data

LevelModel

Required parameters

ELSET

Set this parameter equal to the name of the element set where adaptive mesh refinement is applied.

Optional parameters

COARSENING

This parameter is valid only when ENHANCED CONTACT=NO.

Set COARSENING=YES (default) to specify that refinement can be removed once the refinement criteria are no longer met.

Set COARSENING=NO to specify that refinement cannot be removed even when the refinement criteria are no longer met.

ENHANCED CONTACT

Set ENHANCED CONTACT=YES to activate the enhanced contact formulation that acts to prevent the potential leakage of liquid or gas through the Lagrangian surfaces.

Set ENHANCED CONTACT=NO (default) to deactivate the enhanced contact formulation for the Eulerian-Lagrangian interfaces.

LEVEL

This parameter is valid only when ENHANCED CONTACT=NO.

Set this parameter equal to the maximum number of levels of refinement. The default value is 1.

RATIO

Set this parameter equal to the ratio of the maximum increase in the number of elements during mesh refinement compared to the original number of elements in the specified element set. The default value is 8.0 when ENHANCED CONTACT=NO and is 1.0 when ENHANCED CONTACT=YES.

Data lines to define the criteria used in the mesh refinement when ENHANCED CONTACT=NO

First line
  1. Refinement criteria label (see Defining Adaptive Mesh Refinement in the Eulerian Domain).

  2. Value of the refinement criteria if applicable.

  3. Repeat this data line as often as necessary to define multiple criteria for mesh refinement.

There are no data lines if ENHANCED CONTACT=YES