*ACTIVATE ELEMENTS

Activate elements within a step.

Warning: Development of this capability and user interface is expected to evolve in subsequent releases. Therefore, models may not be upward compatible without modification.

This option is used to turn on a progressive element activation feature within a step definition.

This page discusses:

See Also
*ELEMENT PROGRESSIVE ACTIVATION
In Other Guides
Progressive Element Activation
UEPACTIVATIONVOL

ProductsAbaqus/Standard

TypeHistory data

LevelStep

Required parameters

ACTIVATION
Set this parameter equal to the name assigned to the progressive element activation feature on the ELEMENT PROGRESSIVE ACTIVATION option.

Optional parameters

EIGEN TIME CONSTANT
Set this parameter equal to the time constant used to ramp up eigenstrains at element activation. The default is 0.0.
EXPANSION TIME CONSTANT
Set this parameter equal to the time constant used to ramp up thermal strains at element activation. The default value is 2 times the initial time increment.

Data lines to define progressive element activation

First (and only) line
  1. Table collection name.