You can define an explicit step and request output.
Create a single dynamic, explicit step named
Drop; set the time period to
0.02 s. Accept the default history and field
output requests. In addition, request vertical displacement
(U3), velocity (V3), and acceleration
(A3) history output every 7 × 10−5 s for each
of the three chips.
Tip:
Define the history output request for the first chip; using
the History Output Requests Manager, copy the request and
edit the domain to define the requests for the other chips.
Request history output every 7 × 10−5 s for the logarithmic
strain components (LE11, LE22, and LE12) and the principal logarithmic strains
(LEP) at the top face (section point 5) of the
set BotBoard.