Define a contact interaction property named Fric
. In the Edit Contact Property dialog box, select , select Penalty as the friction formulation, and specify a friction coefficient of 0.3
in the table. Accept all other defaults.
Create a General contact (Explicit) interaction named All
in the Drop
step. In the Edit Interaction dialog box, accept the default selection of All* with self for the Contact Domain to specify self-contact for the default unnamed, all-inclusive surface defined automatically by Abaqus/Explicit. This method is the simplest way to define contact inĀ Abaqus/Explicit for an entire model. Select Fric