Context: The anneal procedure can be created following a dynamic, explicit procedure or a dynamic fully coupled thermal-stress procedure using explicit integration (see Configuring a dynamic, explicit procedure and Configuring a dynamic fully coupled thermal-stress procedure using explicit integration.) During the anneal procedure Abaqus/Explicit sets all appropriate state variables to zero. These variables include stresses, backstresses, plastic strains, and velocities. In the case of metal porous plasticity, the void volume fraction is also set to zero, such that the material becomes fully dense. There is no time scale in an annealing step; therefore, time does not advance. The annealing process occurs instantaneously. No data are required for the anneal procedure. For more information, see Annealing. |