- From the main menu bar in the Visualization module, select .
The Volume Weighted Average Temperature dialog box appears. - Choose the time for which the average temperature will be calculated:
-
Choose Current step/frame to find the temperature only during the step and frame currently displayed in the viewport.
-
Choose All steps to calculate and plot the temperature over the course of the entire analysis.
- Select the elements in which the average temperature will be calculated. You can select all of the model's elements or a subset.
Click Complete when you are done selecting elements. - Calculate the average temperature.
-
Click Calculate if you selected Current step/frame.
The result is given in the message area at the bottom of the window, for example:
Number of elements picked from viewport: 80
**Volume weighted average temperature for the selected elements
No. of elements used in calculation: 80
Step: Step-1, Frame: 15, Current time: 15.0
WtAvTemp: 199.883326817
Volume: 1575.0
-
Click Plot if you selected All steps.
A time history X–Y plot is displayed in the current viewport. If desired, you can change the default curve name for the history plot.
|