- From the main menu bar, select .
- In the Create Contact Controls dialog box that appears, do the following:
- Click Continue to close the Create Contact Controls dialog box.
The Edit Contact Controls dialog box appears. - By default, the maximum number of increments between global contact searches is 4 for self-contact interactions and 100 for surface-to-surface contact interactions. If you want to specify the maximum number of increments between global searches, toggle on Specify max number of increments in the Global Search Frequency portion of the editor and enter a value.
- By default, Abaqus/Explicit uses techniques for local contact searches (local tracking) that use a minimum amount of computational time. If you have difficulty enforcing the appropriate contact conditions, you can toggle off Fast local tracking to use a more conservative local contact search. This setting applies only for surface-to-surface contact interactions.
- In the Penalty stiffness scaling factor field, enter a value for the factor by which Abaqus/Explicit will scale the default penalty stiffness to obtain the stiffnesses used for the penalty contact pairs. The default value is 1.
-
In the Warp check increment field, enter the number of
increments between checks for highly warped facets on main surfaces. The default
value is 20. More frequent checks will cause a slight increase in computational
time.
- In the Angle criteria for highly warped facet (degrees) field, enter a value for the out-of-plane warping angle (in degrees) at which Abaqus/Explicit will consider a facet to be highly warped. The out-of-plane warping angle is defined as the amount of variation of the surface normal over a facet. The default value is 20°.
- Click OK to create the contact controls and to close the editor.
|