You analyzed Model-A
containing Step-1
, Step-2
, and Step-3
.
Because of a power outage, the analysis ended prematurely at Increment 17
of Step-2
.
You requested that restart information be saved every 10 increments. As a result, the last restart information was saved at Increment 10
of Step-2
.
The following procedure describes how you can recover the analysis using the last restart information that was saved:
Copy Model-A
to a new model, say Model-A-recover
, and make Model-A-recover
the current model.
From the main menu bar, select . From the Edit Model Attributes dialog box that appears, do the following:
Toggle on Read data from job, and enter Job-A
to indicate the job from which the restart data will be read.
Set the restart location:
Enter Step-2
to indicate the step from which the restart data will be read.
Choose Restart from increment, interval, iteration, or cycle, and enter 10
to indicate the increment from which the restart data will be read.
Choose and complete the step. Step-2
will continue the analysis after increment 10
and run to completion.
Copy Job-A
to a new job, say Job-A-recover
, that uses Model-A-recover
. Abaqus/CAE sets the job type to Restart
.
Submit Job-A-recover
for analysis.