Tips on Defining Restrictions

  • The element group for a certain restriction should be a subset of the design element group. If this is not the case, SIMULIA Tosca Structure will stop the optimization.
  • The DVCON_SIZING ID_NAME must be referenced in the OPTIMIZE command in order to activate the restriction. In Tosca Structure.gui, the DVCON_SIZING entry must be activated in the OPTIMIZE mask.
  • 
    OPTIMIZE
      ...
      DVCON = name_of_dvcon_entry 
      ...
    END_
    
  • Each geometrical restriction reduces the possibilities of the solution. Thus, it is necessary to add only the restrictions needed for solving the problem. It is still possible to find a solution if too many restrictions are defined, but the result will most probably be suboptimal compared to the optimal design. Therefore, the first step for the user is to perform an optimization without restrictions to obtain knowledge about the restrictions needed for the specific problem.
  • It is impossible to combine all manufacturing constraints at random. The user must be careful when combining conflicting restrictions.

See Also
In Other Guides
DVCON_SIZING