** Mass scaling verification: Test of *FIXED MASS SCALING, SETEQUALDT, FACTOR ** *HEADING *RESTART,WRITE *NODE,NSET=NALL 1, 0.0, 5. 2, 2.0, 5. 3, 2.0, 8. 4, 0.0, 8. 101, 10.0, 5. 102, 12.0, 5. 103, 12.0, 8. 104, 10.0, 8. 11, 0.0, 0. 12, 2.0, 0. 13, 2.0, 3. 14, 0.0, 3. 111, 10.0, 0. 112, 12.0, 0. 113, 12.0, 3. 114, 10.0, 3. *NSET,NSET=DISP 2,102,12,112 *NSET,NSET=FIXED 1,101,11,111 *ELEMENT,TYPE=CPE3,ELSET=REFA 1, 1,2,3 2, 1,3,4 *ELEMENT,TYPE=CPS3,ELSET=REFB 101, 101,102,103 102, 101,103,104 *ELEMENT,TYPE=CPE3,ELSET=TESTA 11, 11,12,13 12, 11,13,14 *ELEMENT,TYPE=CPS3,ELSET=TESTB 111, 111,112,113 112, 111,113,114 *ELSET,ELSET=TEST TESTA,TESTB *ELSET,ELSET=EALL REFA,REFB,TESTA,TESTB *SOLID SECTION,ELSET=REFA,MATERIAL=REFA *SOLID SECTION,ELSET=REFB,MATERIAL=REFB 0.5, *SOLID SECTION,ELSET=TESTA,MATERIAL=TESTA *SOLID SECTION,ELSET=TESTB,MATERIAL=TESTB 0.5, *MATERIAL,NAME=REFA *ELASTIC 1.E6, .2 *DENSITY 1.E-4, *MATERIAL,NAME=REFB *ELASTIC 1.E6, .2 *DENSITY 1.E-4, *MATERIAL,NAME=TESTA *ELASTIC 1.E6, .2 *DENSITY 4.E-4, *MATERIAL,NAME=TESTB *ELASTIC 1.E6, .2 *DENSITY 2.5e-5, *BOUNDARY FIXED,1,2 DISP,2 *AMPLITUDE,NAME=SMOOTH,DEFINITION=SMOOTH STEP 0.,0., .00015, 1. *NSET,NSET=QA_TEST_FIXED FIXED, ** *STEP *DYNAMIC,EXPLICIT ,.00015 *FIXED MASS SCALING,TYPE=SET EQUAL DT,DT=1.213984E-05,FACTOR=2.0,ELSET=TEST *BOUNDARY,AMP=SMOOTH DISP, 1,1, .00075 *RESTART,WRITE,NUMBER INTERVAL= 20 *FILE OUTPUT,NUMBER INTERVAL=4,TIMEMARKS=YES *NODE FILE, NSET=FIXED RF, *ENERGY FILE ***EL FILE **EMSF, EDT ***OUTPUT,HISTORY,TIME INTERVAL=0. ***NODE OUTPUT,NSET=FIXED **RF, *OUTPUT, FIELD, NUMBER INTERVAL=4, TIMEMARKS=YES *NODE OUTPUT, NSET=QA_TEST_FIXED RF, *OUTPUT,FIELD,VARIABLE=PRESELECT *OUTPUT,HISTORY,VARIABLE=PRESELECT,TIMEINT=3.75E-05 *END STEP