*Heading Test for rate dependent uniaxial behavior. The loading/unloading traces the rate dependent curves according to the applies loading rate. *preprint, model=yes *NODE,NSET=NALL3D 1,0.,0.,0. 2,10.,0.,0. *ORIENTATION,SYS=RECT,NAME=ORIGLOB 1.,0.,0.,0.,1.,0. 3,0. *ELEMENT,TYPE=CONN3D2,ELSET=TESTTF 1,1,2 *CONNECTOR SECTION,ELSET=TESTTF,BEHAVIOR=TBTF AXIAL, ORIGLOB, ** *CONNECTOR BEHAVIOR,NAME=TBTF **, integration=explicit ***connector constitutive reference **1.25 *connector uniaxial behavior, component=1 *loading data, direction=tension, type=elastic, rate dependent 0.01,0.005,2 0, 0 , 0. 400, 4.0, 0. 0, 0 , 0.125 450, 4.0, 0.125 ** 0, 0 , 0.25 **500, 4.0, 0.25 0, 0 , 0.375 550, 4.0, 0.375 ** 0, 0 , 0.5 **600, 4.0, 0.5 0, 0 , 0.625 650, 4.0, 0.625 ** 0, 0 , 0.75 **700, 4.0, 0.75 0, 0 , 0.875 750, 4.0, 0.875 0, 0 , 1 800, 4.0, 1 *unloading data, definition=interpolated curve, rate dependent 0, 0 , 0. 400, 4.0, 0. 0, 0 , 0.125 375, 4.0, 0.125 ** 0, 0 , 0.25 **350, 4.0, 0.25 0, 0 , 0.375 325, 4.0, 0.375 ** 0, 0 , 0.5 **300, 4.0, 0.5 0, 0 , 0.625 275, 4.0, 0.625 ** 0, 0 , 0.75 **250, 4.0, 0.75 0, 0 , 0.875 225, 4.0, 0.875 0, 0 , 1 200, 4.0, 1 *loading data, direction=compression, type=permanent Deform, extrapolation=linear 0, 0 400, 1.0 600, 4.0 *unloading data, definition=quadratic 0.6, 0.4 ** *BOUNDARY 1,1,6 2,2,6 *ELEMENT, TYPE=MASS, ELSET=MASS 4001, 1 4002, 2 *MASS, ELSET=MASS 1.E-1 *NSET,NSET=QA_TEST_NALL3D NALL3D, **------------------------------------------------ *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1. *boundary, type=velocity 2,1,1,0.25 *OUTPUT,HISTORY, freq=10 *ELEMENT OUTPUT,ELSET=TESTTF CTF1,CUF1,CU1 *OUTPUT, FIELD, NUMBER INTERVAL=1 *NODE OUTPUT, NSET=QA_TEST_NALL3D U, *OUTPUT,HISTORY,VARIABLE=PRESELECT, freq=10 ***OUTPUT,HISTORY,VARIABLE=PRESELECT *ENDSTEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity 2,1,1,.5 *END STEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity 2,1,1,.75 *END STEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity 2,1,1,1.0 *END STEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity 2,1,1,-0.25 *END STEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity **2,1,1,0.0 2,1,1,-0.5 *END STEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity **2,1,1,0.0 2,1,1,-0.75 *END STEP *STEP,NLGEOM=YES *DYNAMIC, EXP, DIRECT USER CONTROL 1.e-4,1.0 *boundary, type=velocity **2,1,1,0.0 2,1,1,-1.0 *END STEP