This parameter sets the termination criterion for NLPQLP. The NLPQLP stopping
algorithm uses several alternative convergence checks, with the main
convergence parameter based on the Karush-Kuhn-Tucker necessary optimality
condition and the complementary slackness. Termination accuracy is applied
in such a way that the scale of the objective and constraint parameters
has little or no effect on the convergence check. The accuracy of the gradients calculation must be considered when
selecting the Termination Accuracy value. If the
subflow outputs are accurate up to 8–10 digits and the calculated gradients
have at least 7 accurate digits, the recommended Termination
Accuracy value is . If the gradient’s accuracy
is lower, the Termination Accuracy value must
be increased to . The value type is real. The default
value is . Other possible values are . |